Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros

Base de dados
Assunto principal
Tipo de documento
Intervalo de ano
1.
PLoS One ; 18(6): e0287107, 2023.
Artigo em Inglês | MEDLINE | ID: covidwho-20242214

RESUMO

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the causative agent of coronavirus disease 2019 (COVID-19). RT-PCR detection of viral RNA represents the gold standard method for diagnosis of COVID-19. However, multiple diagnostic tests are needed for acute disease diagnosis and assessing immunity during the COVID-19 outbreak. Here, we developed in-house anti-RBD IgG and IgA enzyme-linked immunosorbent assays (ELISAs) using a well-defined serum sample panel for screening and identification of human SARS-CoV-2 infection. We found that our in-house anti-SARS-CoV-2 IgG ELISA displayed a 93.5% sensitivity and 98.8% specificity whereas our in-house anti-SARS-CoV-2 IgA ELISA provided assay sensitivity and specificity at 89.5% and 99.4%, respectively. The agreement kappa values of our in-house anti-SARS-CoV-2 IgG and IgA ELISA assays were deemed to be excellent and fair, respectively, when compared to RT-PCR and excellent for both assays when compared to Euroimmun anti-SARS-CoV-2 IgG and IgA ELISAs. These data indicate that our in-house anti-SARS-CoV-2 IgG and IgA ELISAs are compatible performing assays for the detection of SARS-CoV-2 infection.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Teste para COVID-19 , Técnicas de Laboratório Clínico/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Sensibilidade e Especificidade , Anticorpos Antivirais , Imunoglobulina G , Padrões de Referência , Imunoglobulina A , Imunoglobulina M
2.
Microbiol Spectr ; : e0263922, 2022 Nov 29.
Artigo em Inglês | MEDLINE | ID: covidwho-2137472

RESUMO

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is found in regions where dengue (DENV) and chikungunya (CHIKV) viruses are endemic. Any serological cross-reactivity between DENV, CHIKV, and SARS-CoV-2 is significant as it could lead to misdiagnosis, increased severity, or cross-protection. This study examined the potential cross-reactivity of anti-DENV and CHIKV antibodies with SARS-CoV-2 using acute and convalescent-phase samples collected before the SARS-CoV-2 pandemic. These included healthy, normal human (NHS, n = 6), CHIKV-positive (n = 14 pairs acute and convalescent), primary DENV-positive (n = 20 pairs), secondary DENV-positive (n = 20 pairs), and other febrile illnesses sera (n = 23 pairs). Samples were tested using an in-house SARS-CoV-2 and a EUROIMMUN IgA and IgG ELISAs. All NHS samples were negative, whereas 3.6% CHIKV, 21.7% primary DENV, 15.7% secondary DENV, and 10.8% febrile diseases sera resulted as anti-SARS-CoV-2 antibody positive. The EUROIMMUN ELISA using spike 1 as the antigen detected more positives among the primary DENV infections than the in-house ELISA using spike 1-receptor binding domain (RBD) protein. Among ELISA-positive samples, four had detectable neutralizing antibodies against SARS-CoV-2 reporter virus particles yet none had detectable neutralizing antibodies against the live Wuhan strain of SARS-CoV-2. These data demonstrated the SARS-CoV-2 diagnostic cross-reactivity, but not neutralizing antibody cross-reactivity, among dengue seropositive cases. IMPORTANCE SARS-CoV-2 continues to cause significant morbidity globally, including in areas where DENV and CHIKV are endemic. Reports using rapid diagnostic and ELISAs have demonstrated that serological cross-reactivity between DENV and SARS-CoV-2 can occur. Furthermore, it has been observed that convalescent DENV patients are at a lower risk of developing COVID-19. This phenomenon can interfere with the accuracy of serological testing and clinical management of both DENV and COVID-19 patients. In this study, the cross-reactivity of primary/secondary anti-DENV, CHIKV, and other febrile illness antibodies with SARS-CoV-2 using two ELISAs has been shown. Among ELISA-positive samples, four had detectable levels of neutralizing antibodies against SARS-CoV-2 reporter virus particles. However, none had detectable neutralizing antibodies against the live Wuhan strain of SARS-CoV-2. These data demonstrated SARS-CoV-2 diagnostic cross-reactivity, but not neutralizing antibody cross-reactivity, among dengue seropositive cases. The data discussed here provide information regarding diagnosis and may help guide appropriate public health interventions.

3.
Microbiol Resour Announc ; 10(48): e0087721, 2021 Dec 02.
Artigo em Inglês | MEDLINE | ID: covidwho-1571151

RESUMO

We report coding-complete genome sequences of 44 severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) strains of the alpha and delta variants identified from patients in Kamphaeng Phet, Thailand. Two nonsense mutations in open reading frame 3a (ORF3a) (G254*) and ORF8 (K68*) were found in the alpha variant sequences. Two lineages of the delta variant, B.1.617.2 and AY.30, were found.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA